ThermostatMode Schema
sdm.devices.traits.ThermostatMode
This trait belongs to device types of THERMOSTAT that support different thermostat modes.
Fields
Field | Description | Data Type |
---|---|---|
availableModes |
List of supported thermostat modes. | array(string) Value: ["HEAT", "COOL", "HEATCOOL", "OFF"] |
mode |
The current thermostat mode. | string Values: "HEAT", "COOL", "HEATCOOL", "OFF" |
Sample GET request and response
Request
GET /enterprises/project-id/devices/device-id
Response
{
"name" : "enterprises/project-id/devices/device-id",
"traits" : {
"sdm.devices.traits.ThermostatMode
" : {
"availableModes" : ["HEAT", "COOL", "HEATCOOL", "OFF"],
"mode" : "COOL"
}
}
}
Commands
SetMode
Change the thermostat mode.
SetMode request and response
Request
POST /enterprises/project-id/devices/device-id:executeCommand
{
"command" : "sdm.devices.commands.ThermostatMode.SetMode
",
"params" : {
"mode" : "HEAT"
}
}
Response
{}
SetMode request fields
Field | Description | Data Type |
---|---|---|
mode |
The mode to change the thermostat to. | string Values: "HEAT", "COOL", "HEATCOOL", "OFF" |
Errors
The following error code(s) may be returned in relation to this trait:
Error Message | RPC | Troubleshooting |
---|---|---|
Command not allowed in current thermostat mode. | FAILED_PRECONDITION |
Some thermostat models do not support changing the Eco mode when the thermostat mode is OFF, according to the ThermostatMode trait. The thermostat mode must be changed to HEAT, COOL, or HEATCOOL prior to changing the Eco mode. |
See the API Error Code Reference for the full list of API error codes.